Use
Flow furnaces, ferrite firing furnaces, and other atmosphere and combustion management applications
The TF-30 sensor is a 2-cell limiting current method that uses the current output of a controlled sensor.
|
Model |
TF-30D201 |
|
Measurement principle |
Zirconia 2-cell pump system |
|
Measurement range |
0-100ppm-0-25% 4 arbitrary ranges can be selected |
|
Linearity |
± 2% FS |
|
Repeatability |
± 1% FS |
|
Response time |
0-1000ppm or less: 60S or less 0-1000ppm or more: 30S or less (T90 response when switching calibration gas) |
|
Analog output |
4-20mA DC (fixed), 0-1, 0-5, 0-10V selectable Proofreading |
|
Proofreading |
Air one-point calibration (standard gas required depending on measurement range) |
|
Mounting |
Piping mounting with dedicated sensor mounting bracket |
|
Measuring method |
Direct mounting, sampling (individual correspondence) |
|
Power supply |
Either AC100,200V or DC24V |
|
Outer type (receiver) |
About W96 × D170 × H96 |
|
Weight |
Sensor approx. 1 kg, receiver approx. 1 kg |